Difference between revisions of "hidden:Replace a tape drive in HPSS"
From Lsdf
Line 16: | Line 16: | ||
Read field "Drive Address" x,y,z,t |
Read field "Drive Address" x,y,z,t |
||
− | ''' |
+ | '''8.2. Reconfigure acsls ''' |
+ | |||
− | '''9.1.log-in on acsls mashine''' |
||
+ | log-in on acsls mashine |
||
− | '''9.2 call cmd_proc ''' |
||
− | + | call cmd_proc |
|
+ | cmd_proc -ql |
||
− | '''ACSSA> display drive * -f serial_num''' |
||
+ | ACSSA> display drive * -f serial_num |
||
− | '''logoff''' |
||
+ | logoff |
||
− | '''''' |
||
+ | |||
'''9.3. reconfigure the drive in acsls''' |
'''9.3. reconfigure the drive in acsls''' |
||
'''config drive x,y,z''' |
'''config drive x,y,z''' |
Revision as of 18:55, 17 November 2017
Replace a tape drive in HPSS
1. log-in on core 2. call hpss gui: /opt/hpss/bin/hpssgui.pl & 3. Select Device/Drive List (if necessary choose preferency "Movers(tape)") 4. select the drive to be replaced 5. set "locked" the drive to be replaced: Device Administration-->Lock and Drive Administration-->Lock 6. drive is ready for replacing 7. replace the drive in the tape library 8. Reactivate the replaced drive in hpss 8.1 Show the drive configuration in hpss gui: Select the drive Choose Configure Read field "Drive Address" x,y,z,t 8.2. Reconfigure acsls log-in on acsls mashine call cmd_proc cmd_proc -ql ACSSA> display drive * -f serial_num logoff 9.3. reconfigure the drive in acsls config drive x,y,z Drive id Old Type New Type chg Drive Serial Number -------- -------- -------- ----------------------- 0 T1D unchanged * 579004007294 9. reconfigure the drive in hpss change filed configure-->Device Name-->Update ' 10. unlock the drive in hpss Devices and Drives-->select the drive Device Administration-->Unlock Drive Administration-->Unlock ' ' ' Read filed "Mover" "that is the mover the drive is connected to" 7.2 log-in on the mover shown on step 7.1 7.2 ls -l /dev/hpss