hidden:Replace a tape drive in HPSS: Difference between revisions
From Lsdf
Jump to navigationJump to search
No edit summary |
No edit summary |
||
Line 25: | Line 25: | ||
'''1.4 drive is ready for replacement''' |
'''1.4 drive is ready for replacement''' |
||
'''2. |
'''2. replace the drive in the tape library''' |
||
'''2.1 Physical exchange''' |
|||
Physical exchange of the drive is done by oracle engineer. |
Physical exchange of the drive is done by oracle engineer. |
||
If neccessary, set the IP adress, documented in |
If neccessary, set the IP adress, documented in |
||
https://team.kit.edu/sites/scc-sdm/Dokumente/Data_Protection/Hardware/HardwareListDataProtection.xlsx?Web=1 |
https://team.kit.edu/sites/scc-sdm/Dokumente/Data_Protection/Hardware/HardwareListDataProtection.xlsx?Web=1 |
||
'''7. replace the drive in the tape library''' |
|||
⚫ | |||
'''2.1 documantation of exchange''' |
|||
⚫ | |||
http://wiki.scc.kit.edu/lsdf/index.php/hidden:System_Logs_(HPSS,_TSM) |
http://wiki.scc.kit.edu/lsdf/index.php/hidden:System_Logs_(HPSS,_TSM) |
||
'''8. Reactivate the replaced drive in hpss''' |
'''8. Reactivate the replaced drive in hpss''' |
||
'''8.1 Show the drive configuration in hpss gui:''' |
'''8.1 Show the drive configuration in hpss gui:''' |
Revision as of 15:20, 7 May 2019
Replace a tape drive in HPSS
A call at Oracle should be generated automatically for T10KD drives.
Otherwise open a service request at Oracle https://support.oracle.com with the Tray Serial Number.
The Tray Serial Number of the drive can be determined via SL-Console or in file
https://team.kit.edu/sites/scc-sdm/Dokumente/Data_Protection/Hardware/HardwareListDataProtection.xlsx?Web=1
When the call at Oracle was opened, please set the Icinga State for the Check "Drive_Trap" of the corresponding library to OK: https://icinga.scc.kit.edu/icinga-web
1. preparation of replacement 1.1 log-in on hpss core 1.2 call hpss gui /opt/hpss/bin/hpssgui.pl & 1.3 set drive "locked" select Monitor: Device/Drive List (if necessary choose Preferences "Movers(tape)") select the drive to be replaced set "locked" the drive to be replaced: Device Administration-->Lock and Drive Administration-->Lock 1.4 drive is ready for replacement
2. replace the drive in the tape library
2.1 Physical exchange Physical exchange of the drive is done by oracle engineer. If neccessary, set the IP adress, documented in https://team.kit.edu/sites/scc-sdm/Dokumente/Data_Protection/Hardware/HardwareListDataProtection.xlsx?Web=1 2.1 documantation of exchange insert documentation of the replacement in LSDF Wiki (System Logs): http://wiki.scc.kit.edu/lsdf/index.php/hidden:System_Logs_(HPSS,_TSM)
8. Reactivate the replaced drive in hpss 8.1 Show the drive configuration in hpss gui: Select the drive Choose Configure Read field "Drive Address" x,y,z,t 8.2. Reconfigure acsls log-in on acsls mashine (scc-stk-lib01, 172.21.238.64) cmd_proc -ql ACSSA> display drive * -f serial_num ACSSA>logoff 8.3. reconfigure the repalaced drive in acsls config drive x,y,z Drive id Old Type New Type chg Drive Serial Number -------- -------- -------- ----------------------- 0 T1D unchanged * 579004007294 NOTICE: "drive id" is the number t read from Step 8.1 8.4. reconfigure the drive in hpss log-in HPSS GUI Devices and Drives-->select the drive Read field "Mover" "that is the mover the drive is connected to" log-in on the mover shown on previous step ls -l /dev/hpss --> note the new SerialNumber change field configure-->Device Name with the new device read from mover Press Update at the bottom of the window 8.5. unlock the drive in hpss Devices and Drives-->select the drive Device Administration-->Unlock Drive Administration-->Unlock 8.6 check documentation of drive exchange in LSDF Wiki (System Logs) Check if exchange was documented: http://wiki.scc.kit.edu/lsdf/index.php/hidden:System_Logs_(HPSS,_TSM) 8.7 Update Device Name on the StorSentry GUI Reboot Storsentry, if neccessary, to add the new drive into the scsi layer Afterwards do an update to the configuration if the drive is not seen [root@storsentry-test ~]# /opt/histor/storsentry/agent/support/Update_config.sh Start the GUI and verify the exchange, the new drive will be seen by its serial number. StorSentry GUI: Administration: Log in (no password) Rename the replaced drive from DriveName to DriveName-removed. Rename the new drive from "SerialNumber of the new drive" to DriveName.